Alkyd Finish-Multicolor

Alkyd Finish-Multicolor

Product Description:

- Model: 725-C43-1

- One-component alkyd resin finish

- Obtain a low spread fireworks certificate from CCS.

- VOC less than 420g/L

Intended Uses

- A cosmetic finish.

- For use in all above water areas.

- For use in all above water areas.

- For use at Newbuilding, Maintenance and Repair or On Board Maintenance.

Product Information

Volume Solids:50%±3%                  Finish/Sheen: Gloss

Film Thickness(μm)

Min

Typical

Max

Dryfilm Thickness

30

40

80

Wetfilm Thickness

60

80

160

Theoretical Coverage(m2/L)

16.7

12.5

6.2

Mix Ratio:One pack

Method of Application

 

Airless Spray

Recommended

Tip size range:0.38-0.53mm

Output pressure:17MPa

Air Spray

Tip size range:2.0-3.0mm

Output pressure:0.4MPa

Brush/Roller

For small area only

Thinner

Not recommended. Use BX-801 only in exceptional circumstances (volume 5%).

Cleaner

CX-101

Induction Period

Not applicable

 Drying Information 

 

-5℃

5℃

25℃

35℃

Touch Dry

5h

3h

 1.5h

1h

Hard Dry

60h

48h

24h

16h

Pot Life

Not applicable

Overcoating Data

-5℃

5℃

25℃

35℃

Min Max

Min Max

Min Max

Min Max

48h

24h

16h

12h

Storage:

Store in cool and dry conditions,Well ventilate.Keep away from hot and fire. Shelf Life: 12 months

minimum at 25 ℃,Subject to re-inspection thereafter.

Pack Size: 22kg/18L in 20 L container.

Flash Point: Greater than 28℃.

Systems and Compatibility: 

Consult your Sunrui Representative for the systems best suited for the surfaces to be protected.

 Surface Preparation:

High pressure fresh water wash or fresh water wash, as appropriate, and remove all oil or grease, soluble contaminants and other foreign matter in accordance with SSPC-SP1 solvent cleaning. All surfaces to be coated should be clean, dry and free from contamination.

Newbuilding/Major Refurbishment 

725-C43-1 should be applied over a recommended primer coating scheme. The primer surface should be clean, dry and free from contamination.

725-C43-1 must be applied within the coating interval specified (consult the relevant product data sheet). Areas of breakdown, damage etc. should be prepared to the specified standard (eg.St3) and primed prior to the application of 725-C43-1.

Repair/On Board Maintenance

725-C43-1 may be applied directly over aged 725-C43-1 following thorough fresh water washing and degreasing provided the coating to be overcoated is in an intact and tightly adherent condition. Loose or flaking coatings should be removed back to a firm edge and an appropriate primer should be used to repair the area before application of the full coat.

Limitations:

725-C43-1 is not suitable for use on immersed areas. Apply in good weather. Temperature of the surface to be coated must be least 3 above the dew point when the humidity is lower than 85%.

The dry time and overcoating interval may change according to the environment factors.

Avoiding absorb the solvent steam and paint steam for long time. Skin and eyes must avoid contacting the paint. Pay attention to ventilate and fireproof when applying.

Duty statement:

The data in the sheet base on the information from the laboratory and practice.

The application may exceed the control, so we only ensure our product quality.

We own the right of the data sheet modification without informing.